Uptime Institute Says Power to Cost 300-2250% More Than Server Hardware; What Does This Mean?

I came across Uptime Institute founder Ken Brill's CIO Magazine article via 3tera VP Marketing Bert Armijo's blog.

Ken says while hardware prices are falling, total cost of data center ownership is headed through the roof. 5 years from now, the purchase price for a rack of servers will drop 27.5% from $138K today to just $103K. But while it only takes 15 kilowatts to power that rack right now, the energy requirement will rise to 22 - 170 kilowatts by 2012. It could cost as much as $2.3 million to power/cool $103K worth of gear throughout its 3-year lifespan.

(I'm not sure if this figure includes switches and routers and such. A recent Cisco/APC/Emerson study shows that servers/storage/cooling consume 76% of data center power, with 11% going to networking equipment, 3% lighting, and 10% power conversion losses. If Uptime's calculations didn't take the other 24% into account, Ken's $2.3M becomes over $3M!)

I've been thinking about Ken's stats and trying to understand what they mean. As a point of reference, I was looking at Dell's website, which advertises the 4U PowerEdge 6950 dual core, dual processor Opteron server for about $9K. Is Ken saying that:

(a) This particular machine will cost 27.5% less 5 years from now?

(b) 2012's late model machines will sell for 27.5% less than what's on the market today?

(c) The amount of server hardware that fills up 4U of space will be available for $6500 in 2012?

If we assume he means (c), and we accept Sun's claim that "server performance, power and space efficiencies are improving at up to 40% annually on average, and could double every 2 years", then 4U of space may be able to accommodate not one but 4 servers that each feature 4x more processing power and 4x greater energy efficiency.

In other words, $6,500 could buy you 16x more computing resources than that dual Opteron! If that's the case, you might even be able to afford $1M per rack per year in electricity. But only if you virtualize like crazy. No more leasing data center space per square foot or per rack. No more dedicated servers, either. The average customer won't need 4x more processing power in 5 years, which means you won't be able to justify turning on a whole entire server just for them.

You'd also have to replace hardware early and often. Sun recently announced a refresh service for swapping out your servers at least 3 times over 42 months. At first I thought that sounded wasteful, but if server power efficiency is improving at 40% per year, holding on to old gear might end up costing you more. Again, virtualization would be a must. You wouldn't want customer apps to become attached to machines that will be phased out before long.

Bert from 3tera says changes in data center economics will make it increasingly difficult for enterprise CIOs to justify operating their own facilities. But they won't outsource to traditional colo or dedicated server providers. Instead, he agrees with Cassatt CEO Bill Coleman that in the near-ish future, you'll be "paying for data center horsepower the same way you pay for electricity or gas". I think so too. How about you?

PS - On a somewhat related note, eWeek says Intel will release its "Clovertown" chips today. The quad core processors have a 50 watt thermal envelope, versus 80-120 watts on earlier models. That's a 38-60% drop.

PPS - Also, speaking of the Uptime Institute, check out this SearchDataCenter.com interview on how they've helped The Planet save $10K/month on electricity. The Planet, the article says, is looking to expand beyond Texas into the Midwest.

Comments
Yes as a Server Hosting Center i can tell many stories from other data centers in Denmark ranging from lost e-mails for many weeks, unrecoverable e-mails, downtimes for several weeks and so on.

The Downtime is loss of customers for most shoppingcarts, and the actual loss depends on the actual sale from new customers each day.

On the other hand you can protect by using IP Clustering from 2 independant providers. Most Linux and Windows supports this, and if uptime is a key factor, then this is a choice many customers dont know exists. Other factors could be Backup with Disaster Recovery Certification (because as many as 90% of all customers does not have tried or have a plan for Diaster Recovery.

Thanks for a really perfect site!
# Posted By Jane Clausen | 9/4/07 4:44 PM
 
 

Find Web Hosts | Reseller Hosting | Personal Web Hosting | Small Business Web Hosting | Dedicated Servers | Managed Hosting | Adult Web Hosting
Reseller Hosting | Web Hosting Automation | Wholesale Domain Names | Private Label Web Hosting | Web Host Advertising Agencies | Host Services


About WHIR | Online Advertising | Print Advertising | Print Subscription | Email Newsletters | RSS Feeds
 
Submit News | Privacy Policy | Buy Reprints
Web Host Industry Review, Inc. is not responsible for the content of comment submitted by our users.

  © Copyright Web Host Industry Review, Inc.